• EI
  • Scopus
  • 中国科技期刊卓越行动计划项目资助期刊
  • 北大核心期刊
  • DOAJ
  • EBSCO
  • 中国核心学术期刊RCCSE A+
  • 中国精品科技期刊
  • JST China
  • FSTA
  • 中国农林核心期刊
  • 中国科技核心期刊CSTPCD
  • CA
  • WJCI
  • 食品科学与工程领域高质量科技期刊分级目录第一方阵T1
中国精品科技期刊2020
王一凡,于铭心,裴龙英,等. 高清X射线荧光光谱法快速测定干制黑木耳中镉和砷的含量[J]. 华体会体育,2023,44(9):333−339. doi: 10.13386/j.issn1002-0306.2022060260.
引用本文: 王一凡,于铭心,裴龙英,等. 高清X射线荧光光谱法快速测定干制黑木耳中镉和砷的含量[J]. 华体会体育,2023,44(9):333−339. doi: 10.13386/j.issn1002-0306.2022060260.
WANG Yifan, YU Mingxin, PEI Longying, et al. Rapid Detection of Cadmium and Arsenic in Dried Auricularia auricula by High Definition X-ray Fluorescence Spectrometry[J]. Science and Technology of Food Industry, 2023, 44(9): 333−339. (in Chinese with English abstract). doi: 10.13386/j.issn1002-0306.2022060260.
Citation: WANG Yifan, YU Mingxin, PEI Longying, et al. Rapid Detection of Cadmium and Arsenic in Dried Auricularia auricula by High Definition X-ray Fluorescence Spectrometry[J]. Science and Technology of Food Industry, 2023, 44(9): 333−339. (in Chinese with English abstract). doi: 10.13386/j.issn1002-0306.2022060260.

高清X射线荧光光谱法快速测定干制黑木耳中镉和砷的含量

Rapid Detection of Cadmium and Arsenic in Dried Auricularia auricula by High Definition X-ray Fluorescence Spectrometry

  • 摘要: 高清X射线荧光(high definition X-ray fluorescence,HDXRF)光谱技术应用于干制黑木耳样品中镉和砷元素的快速检测。将干制黑木耳样品进行前处理,对样品颗粒粒径、样品量和检测时间等因素进行优化,并评价方法的精密度、重复性和稳定性等。结果表明,最优检测条件为:颗粒粒径100目,样品量0.80 g,检测时间600 s。HDXRF法分析样品的总时间不超过15 min。HDXRF法得到的Cd和As的检出限分别为:0.035和0.012 mg/kg。HDXRF法精密度、重复性和稳定性的相对标准偏差(relative standard deviation, RSD)均低于10%。最后对HDXRF法和电感耦合等离子体质谱(inductively coupled plasma mass spectrometry, ICP-MS)法的检测结果进行比较,其结果的相对误差值均小于20%。说明HDXRF法能够满足干制黑木耳中镉和砷快速检测的要求。

     

    Abstract: The contents of cadmium and arsenic in dried Auricularia auricula were rapidly detected by high definition X-ray fluorescence (HDXRF) spectrometry. In the process of the experiment, the dried Auricularia auricula samples were pre-treated, and the three experimental conditions of particle size, sample weight, and instrument measurement time were optimized. Figures of merit such as precision, reproducibility, and stability were evaluated. The results showed that, the optimal detection conditions of HDXRF were: particle size of 100 meshes, sample weight of 0.80 g, and measurement time of 600 s. This method allowed direct detection of cadmium and arsenic in 15 min, and a detection limit of 0.035 mg/kg of cadmium and 0.012 mg/kg of arsenic, respectively. The relative standard deviations (RSD) of precision, reproducibility and stability of HDXRF were all below 10%. Finally, the results of HDXRF were compared with inductively coupled plasma mass spectrometry (ICP-MS). The results were accurate and the relative errors were less than 20%. It indicates that the method of HDXRF can meet the rapid detection requirements of cadmium and arsenic in dried Auricularia auricula.

     

/

返回文章
返回