• EI
  • Scopus
  • 中国科技期刊卓越行动计划项目资助期刊
  • 北大核心期刊
  • DOAJ
  • EBSCO
  • 中国核心学术期刊RCCSE A+
  • 中国精品科技期刊
  • JST China
  • FSTA
  • 中国农林核心期刊
  • 中国科技核心期刊CSTPCD
  • CA
  • WJCI
  • 食品科学与工程领域高质量科技期刊分级目录第一方阵T1
中国精品科技期刊2020
李颖超,赵良,钱和. 高温高压处理对花生致敏蛋白Ara h1及其免疫反应性的影响[J]. 华体会体育,2021,42(20):32−36. doi: 10.13386/j.issn1002-0306.2020120077.
引用本文: 李颖超,赵良,钱和. 高温高压处理对花生致敏蛋白Ara h1及其免疫反应性的影响[J]. 华体会体育,2021,42(20):32−36. doi: 10.13386/j.issn1002-0306.2020120077.
LI Yingchao, ZHAO Liang, QIAN He. Effects of Autoclaving on the Immunoreactive Properties of Allergenic Protein Ara h1 from Peanut Seeds[J]. Science and Technology of Food Industry, 2021, 42(20): 32−36. (in Chinese with English abstract). doi: 10.13386/j.issn1002-0306.2020120077.
Citation: LI Yingchao, ZHAO Liang, QIAN He. Effects of Autoclaving on the Immunoreactive Properties of Allergenic Protein Ara h1 from Peanut Seeds[J]. Science and Technology of Food Industry, 2021, 42(20): 32−36. (in Chinese with English abstract). doi: 10.13386/j.issn1002-0306.2020120077.

高温高压处理对花生致敏蛋白Ara h1及其免疫反应性的影响

Effects of Autoclaving on the Immunoreactive Properties of Allergenic Protein Ara h1 from Peanut Seeds

  • 摘要: 通过免疫学方法研究了高温高压处理后花生主要致敏蛋白Ara h1溶解性和免疫反应性的变化。结果表明:高温高压处理可使Ara h1及花生蛋白粗提物均发生显著变性和分解,以135 ℃处理最为显著;但Ara h1在121和135 ℃处理20 min后均表现出良好的热稳定性,可溶性蛋白含量不再随处理时间延长而发生明显减小;135 ℃处理20 min或更长时间后样品中15 kDa左右或更小分子量的蛋白片段成为分解物的主要组成部分。高温高压处理可使Ara h1的免疫反应性显著下降,且在蛋白粗提物的混合体系中更为显著:135 ℃处理20和60 min后,Ara h1的IgG结合能力分别仅为对照的1/3和1/6;而在混合体系中,相同条件下Ara h1的IgG结合能力分别仅为对照的2/9和1/9。

     

    Abstract: The changes of solubility and immunoreactivity properties of Arah1, the main allergenic protein in peanut, were studied by immunological methods. The results showed that: Autoclaved treatment could significantly denaturate and decompose Ara h1 and peanut protein extracts, especially at 135 ℃; however, Ara h1 showed good thermal stability after 20 min treatment at 121 and 135 ℃, and the soluble protein content did not decrease significantly with the extension of treatment time; after being treated at 135 ℃ for 20 min or longer, main components of decomposition products were those protein fragments with molecular weight of 15 kDa or less. Autoclaving could significantly decrease the immunoreactivity of Ara h1, especially in the mixed system of protein extracts: After being treated at 135 ℃ for 20 and 60 min, the IgG immunoreactivity of Ara h1 was only 1/3 and 1/6 of that of control, respectively; in the mixed system, the IgG immunoreactivity of Ara h1 was only 2/9 and 1/9 of that of control under the same conditions.

     

/

返回文章
返回