• EI
  • Scopus
  • 中国科技期刊卓越行动计划项目资助期刊
  • 北大核心期刊
  • DOAJ
  • EBSCO
  • 中国核心学术期刊RCCSE A+
  • 中国精品科技期刊
  • JST China
  • FSTA
  • 中国农林核心期刊
  • 中国科技核心期刊CSTPCD
  • CA
  • WJCI
  • 食品科学与工程领域高质量科技期刊分级目录第一方阵T1
中国精品科技期刊2020
张修景. CdTe为荧光探针测定罗汉参中的混合氨基酸[J]. 华体会体育, 2015, (06): 62-65. DOI: 10.13386/j.issn1002-0306.2015.06.004
引用本文: 张修景. CdTe为荧光探针测定罗汉参中的混合氨基酸[J]. 华体会体育, 2015, (06): 62-65. DOI: 10.13386/j.issn1002-0306.2015.06.004
ZHANG Xiu-jing. CdTe as fluorescent probe to determine the mixed amino acids in Luohanshen[J]. Science and Technology of Food Industry, 2015, (06): 62-65. DOI: 10.13386/j.issn1002-0306.2015.06.004
Citation: ZHANG Xiu-jing. CdTe as fluorescent probe to determine the mixed amino acids in Luohanshen[J]. Science and Technology of Food Industry, 2015, (06): 62-65. DOI: 10.13386/j.issn1002-0306.2015.06.004

CdTe为荧光探针测定罗汉参中的混合氨基酸

CdTe as fluorescent probe to determine the mixed amino acids in Luohanshen

  • 摘要: 制备一种新型量子点CdTe,建立一种以CdTe为荧光探针测定罗汉参中混合氨基酸的方法。向荧光量子点CdTe溶液中加入Co2+后其荧光强度降低,降低的程度在一定范围内与Co2+浓度成线性关系;加入氨基酸后,荧光强度又得到恢复,而量子点荧光的恢复强度与加入氨基酸的浓度呈线性关系。在混合氨基酸标准溶液2.0×10-85.5×10-7mol/L线性范围内,量子点荧光的恢复强度与混合氨基酸浓度的线性方程为y=1.04×106x+1.013,相关系数R2=0.9995。考察了不同缓冲溶液、pH、Co2+浓度等因素对体系造成的影响。结果表明,在pH=9.5的硼砂缓冲溶液中,2.0×10-5mol/L的Co2+能很好的猝灭CdTe荧光。应用于实际样品测定的相对标准偏差(n=5)为3.0%,加标回收率在98.3%104.4%范围内,检出限为1.1×10-8mol/L。该方法简单、快速,实用性强。 

     

    Abstract: A new type of CdTe quantum dots(QDs) was prepared. The method was established to determine the mixed amino acids in Luohanshen by CdTe as fluorescent probe. After adding the Co2 +fluorescent quantum dots into the CdTe solution,the fluorescence intensity reduced. The reduced extent had a linear relationship with the concentration of Co2 +in a certain range. After adding the amino acids,the fluorescence intensity restored,and the quantum fluorescence intensity was linear with the concentration of amino acids. In the mixed acids standard solution with the linear range of 2.0×10-8mol/L to 5.5×10-7mol/L,the linear equation of the recovery intensity of quantum dots fluorescence and the mixed acids concentration was y =1.04 ×106x +1.013. The correlation coefficient was R2=0.9995. The influence factors on the system caused by the different buffer solution,p H value and Co2+concentration,etc were examined. The result showed that,in borax buffer solution with p H=9.5,the Co2+solution 2.0×10-5mol/L could be better CdTe fluorescence. The relative standard deviation used to measure the acture sample(n=5) was 3.0%. The recovery rate was between 98.3% to 104.4%.The detection limit was 1.1×10-8mol/L. The method was simple,rapid and practical.

     

/

返回文章
返回